Topic |
Rule |
Plot Level |
Plot Area |
For any Residential use if plot is a part of approved layout plan then plot area may be less than 40 sqmt.{Building Construction and Development By-Laws 2018, Rule No. 3.2.1 }
|
Plot Width |
For any Residential use if plot is a part of approved layout plan then plot area may be less than 40 sqmt.{Building Construction and Development By-Laws 2018, Rule No. 3.2.1 }
|
Plot Depth |
For any Residential use if plot is a part of approved layout plan then plot area may be less than 40 sqmt.{Building Construction and Development By-Laws 2018, Rule No. 3.2.1 }
|
Access Width |
For Single dwelling Unit, The width of the main abutting road shall not be less than 9.00 mt.
|
Plot Frontage |
For any Residential use if plot is a part of approved layout plan then plot area may be less than 40 sqmt.{Building Construction and Development By-Laws 2018, Rule No. 3.2.1 }
|
Coverage Area |
For Residential use and Hostel, in location Existing Built Up Area/Developed Area ,if plot area is between 100-300 sq mt. then Max.Coverage shall be 65% applicable{Building Construction and Development By-Laws 2018, Rule No.3.5.1.(1)}
|
Additional Coverage Area |
-
|
FAR Area |
(1)
For Residential use and Hostel, in location Existing Built Up Area/Developed Area ,if plot area is between 100-300 sq mt. then Max.FAR shall be 1.75 applicable{Building Construction and Development By-Laws 2018, Rule No.3.5.1.(1)}
(2)
-
(3)
For Residential use and Hostel, in location Existing Built Up Area/Developed Area ,if plot area is between 100-300 sq mt. then Max.FAR shall be 1.75 applicable{Building Construction and Development By-Laws 2018, Rule No.3.5.1.(1)}
(4)
No Additional FAR is applicable
|
Consumed FAR |
(1)
For Residential use and Hostel, in location Existing Built Up Area/Developed Area ,if plot area is between 100-300 sq mt. then Max.FAR shall be 1.75 applicable{Building Construction and Development By-Laws 2018, Rule No.3.5.1.(1)}
(2)
-
(3)
For Residential use and Hostel, in location Existing Built Up Area/Developed Area ,if plot area is between 100-300 sq mt. then Max.FAR shall be 1.75 applicable{Building Construction and Development By-Laws 2018, Rule No.3.5.1.(1)}
(4)
No Additional FAR is applicable
|
Tree Number |
For the residential Use, for plot area less than 200 sq.mt.,one tree shall be required. {As per Building Construction and Development By-Laws 2018, rule no. 3.1.2.2}
|
Equivalent Car Space Parking Check |
FOR RESIDENTIAL BUILDING, FOR PLOT AREA 100-200 SQ. MT. ONE CAR SHALL BE REQUIRED {AS PER BUILDING CONSTRUCTION AND DEVELOPMENT BY-LAWS 2018, RULE NO.3.10}
|
Total Car Parking Check |
FOR RESIDENTIAL BUILDING, FOR PLOT AREA 100-200 SQ. MT. ONE CAR SHALL BE REQUIRED {AS PER BUILDING CONSTRUCTION AND DEVELOPMENT BY-LAWS 2018, RULE NO.3.10}
|
Margin Rule |
For Row House,plot area above 150 and up to 300 sq. mt., min front 3.0, rear 3.0 shall be required and side margins are not required {Building Construction and Development By-Laws 2018,Rule No. 3.4.1 (I) , (VI)}
|
'' |
''
|
Tenement Density |
FOR RESIDENTIAL LAYOUT PLAN,MAX. 4 DWELLING UNIT FOR PLOT AREA 150-300SQMT.{BUILDING CONSTRUCTION AND DEVELOPMENT BY-LAWS 2018,RULE NO.26}
|
Compound Wall Check |
(1)
Max 1.50m Height for Road abutting compound wall of corner plot shall be permissible as per the By laws table 7.47, Ref 3.8.2 Page 54
(2)
Max 2.40m Height in which 0.9 is for Grill (from center line of the road) for Compound wall shall be permissible as per the By laws Ref 3.8.2 Page 54
|
Building Level |
Building Height |
For Residencial Use, Maximum Height of construction shall be 10.50 mts (For Building without stilt/parking floor) from the level of the Building Unit.{Building Construction and Development By-Laws 2018, 3.4.1 }
|
Floor Height |
(1)
For Terrace floor, atleast 1.0 mt. high and max. upto 1.5 mt. ht. Parapet wall shall be provided {Building Construction and Development By-Laws 2018,}
(2)
For Terrace floor, atleast 1.0 mt. high and max. upto 1.5 mt. ht. Parapet wall shall be provided {Building Construction and Development By-Laws 2018,}
(3)
For any Habitable Floor, minimum Floor height shall be 2.75 mts.{Building Construction and Development By-Laws 2018,}
(4)
The plinth of the habitable area of any building shall be at a minimum height of 0.30mts from the established level of the building unit {Building Construction and Development By-Laws 2018, Rule No. 3.6.5, Page 51}
|
Floor Number |
For any Residential Single Dwelling unit without stilt Maximum Height of construction shall be 10.50 mts having max G+2 floor from the level of the Building Unit.{Building Construction and Development By-Laws 2018, 2.5.1.7 }
|
Carpet Area Check |
SPLIT A
|
OTS |
(1)
Double height area and width should not be checked.
(2)
-
|
OTS Count |
(1)
Double height area and width should not be checked.
(2)
-
|
StairCase Count |
(1)
For any building having more than one Ground floor, Mini. one staircase has to be provided
(2)
No staircase check should be mandatory for Terrace floor.
|
StairCase |
(1)
For Residential Building,stairwidth shall be mini. 1.0 mt. with max riser upto 0.19 mt. and min. tread upto 0.25 mt.{Building Construction and Development By-Laws 2018, Rule No.3.8.1, Page 54}
(2)
-
(3)
For nay Residential Building, The number of risers shall be 12.00 per flight for Stairs.{Building Construction and Development By-Laws 2018,}
(4)
For any use staircase check should not be mandatory on terrace floor.{Building Construction and Development By-Laws 2018, Rule No.3.8.1 }
(5)
-
(6)
For nay Residential Building, The number of risers shall be 12.00 per flight for Stairs.{Building Construction and Development By-Laws 2018,}
|
Building Level (Rooms) |
Bed Room
|
Minimum size of Any habitable room shall be 9.50 sq. mt.{Building Construction and Development By-Laws 2018, Rule No.3.6.1} ; - |
Dining/kitchen
|
Minimum size of habitable room shall be 9.50 sq. mt.{Building Construction and Development By-Laws 2018} ; - |
Drawing Room
|
Minimum size of Any habitable room shall be 9.50 sq. mt.{Building Construction and Development By-Laws 2018, Rule No.3.6.1} ; - |
Living
|
Minimum size of Any habitable room shall be 9.50 sq. mt.{Building Construction and Development By-Laws 2018, Rule No.3.6.1} ; - |
Store
|
No rule defined{Building Construction and Development By-Laws 2018, Rule No.3.6.1} ; - |
Toilet
|
Minimum size of Bath +WC room shall be 2.80 sq. mt.{Building Construction and Development By-Laws 2018} ; - |