[-] Proposal Information (Table 1)
General Details
AuthorityLucknow Development Authority
AuthorityClassCategory A
AuthorityGradeDevelopment Authority (DA)
Inward_NoLDA/BP/22-23/2235
Application TypeGeneral Proposal
CaseTrackRegular
Project TypeBuilding Permission
Nature of DevelopmentNEW
Development AreaDeveloped Area
SubDevelopment AreaMetro City Area
Special ProjectNA
Site AddressDistrict:Lucknow,Tehsil:Lucknow,Village:NA
LTP Details
TypeArchitect
NameAMAN KUMAR
License No.AM1992328/15092021
Mobile No8188884641
AddressVILL ANOOP KHERA POST MATI POLICE STATION BANTHARA DISTRICT LUCKNOW 226002
RemarkLTP
  Schedule of boundaries
Plot Use Residential
Plot SubUse Row House
Development Plan Rashmi Khand Raibarilly Road
Land Use Zone Residential use Zone
Land SubUse Zone Residential Zone
Layout Type NA
Abutting Road Width 9.00
     
[-]Owner/Applicant details
NameSMT NIHARIKA GAUTAM
Email IDNiharikagautam1969@gmail.com
Mobile No7991256488
     
[-] Applicants Details
NameAMAN KUMAR
Validity16/09/2026
EMAIL IDamankumar96ydv@gmail.com
Mobile Number8188884641
 
[-] Plot Details (Table 2)
Area as per Drawing : 169.16
[-] Table 2b
Proposal Detail
Unit
Development Detail
Plot PLOT
Plot Use Residential
Plot Sub Use Row House
Gross Plot Area 169.16
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 169.16

[-] Area From Document (Table 2a)
No. Form Area
1 Document Area 171.00
2 Net Plot Area 169.16

Minimum area of Plot Considered : 169.16

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.91 %) 119.95
        Previous Coverage area ( 75.00 %) 75.00
        Current Coverage area ( 65.00 %) 44.95
Proposed Coverage Area ( 52.03 %) 88.01
Total Prop. Coverage Area ( 52.03 %) 88.01
Balance coverage area ( 18.88 %) 31.94
FAR CHECK
    Perm. FAR Area ( 1.90 ) 321.03
        Previous Perm. FAR Area ( 2.00 ) 200.00
        Current Perm. FAR Area ( 1.75 ) 121.03
Total Perm. FAR area ( 1.90 ) 321.03
    Residential FAR 222.88
Total Building FAR Area 222.88
Total Proposed FAR Area 222.88
Consumed FAR (Factor) 1.32
Balance FAR Area 98.15
BUA CHECK
Total BuiltUp Area 239.67

Approved Layout Details
   
Layout Approved Details
Layout Approved Common COP Provided Common Parking Provided
Yes No No





[-] Check List
Name Description Unit Reqd Perm Proposed Status
[-] Plot Details
PLOT Plot Area Sq.Mt. - - 169.16 OK
Plot Width Sq.Mt. - - 8.92 OK
Plot Depth Sq.Mt. - - 18.97 OK
Access Width Sq.Mt. 9.00 - 9.00 OK
Plot Frontage Sq.Mt. - - 8.92 OK
Coverage Area Sq.Mt. - 119.95 88.01 OK
FAR Area Sq.Mt. - 321.03 222.88 OK
Additional FAR Area Sq.Mt. - - - OK
FOC FAR Area Sq.Mt. - - - OK
Consumed FAR Sq.Mt. - 1.90 1.32 OK
[-] Additional Coverage Area
PLOT Additional Coverage Area Sq.Mt. - - 0.00 OK
[-] Tree
Tree PLOT - Tree - Nos Of Trees No. 1 3 OK
[-] Parking
Equivalent Car Space In Area Sq.Mt. - - 13.75 OK
Equivalent Car Space-No. No. - - 1.00 OK
Total Car In Area Sq.Mt. 13.75 - 13.75 OK
Total Car-No. No. 1.00 - 1.00 OK
Total In Area Sq.Mt. 13.75 - 13.75 OK
[-] PWork to Plot Setback
A-1 (A)...Building Max Setback Front Margin... 9.0 M. WIDE MAIN ROAD Mt. 3.00 - 3.00 OK
Rear Margin Mt. 3.00 - 3.00 OK
Side1 Margin Mt. - - 0.00 OK
Side2 Margin Mt. - - 0.00 OK
[-] Permissible Area in Rear Setback
Permissible Area in Rear Setback A-1 (A) - Perm Area Mt. 10.69 10.60 OK
[-] Tenements Density Check
4/Hec. No Of Tenements No. - 5 1 OK
No Of Persons No. - - - OK
[-] Building Height
A (A) Height Mt. 10.50 9.45 OK
Building Length Mt. - 15.97 OK
Height Mt. 9.45 OK
Height In Rear SetBack Mt. 7.00 6.45 OK
[-] Floor Height
A (A) Parapet at Terrace Floor - Height Mt. - 1.50 1.00 OK
Parapet at Terrace Floor - Clear Height Mt. - - 1.00 OK
Second Floor - Height Mt. - - 3.00 OK
Second Floor - Clear Height Mt. 2.75 - 2.85 OK
First Floor - Height Mt. - - 3.00 OK
First Floor - Clear Height Mt. 2.75 - 2.85 OK
Ground Floor - Height Mt. - - 3.00 OK
Ground Floor - Clear Height Mt. 2.75 - 2.85 OK
Plinth - Height Mt. 0.30 - 0.45 OK
Plinth - Clear Height Mt. - - 0.45 OK
[-] Floors Number
A (A) No. of Floors No. G + 2 G + 2 OK
No. of Units No. 1 1 OK
[-] Carpet Area Check
A (A) GROUND FLOOR PLAN - SPLIT A - Area Sq.mt. - - 86.07 OK
FIRST FLOOR PLAN - SPLIT A - Area Sq.mt. - - 80.12 OK
SECOND FLOOR PLAN - SPLIT A - Area Sq.mt. - - 51.51 OK
[-] OTS Details
A (A) GROUND FLOOR PLAN - OTS - Area Sq.Mt. - 7.50 OK
GROUND FLOOR PLAN - OTS - Width Mt. - 2.50 OK
FIRST FLOOR PLAN - OTS - Area Sq.Mt. - 7.50 OK
FIRST FLOOR PLAN - OTS - Width Mt. - 2.50 OK
SECOND FLOOR PLAN - OTS - Area Sq.Mt. - 7.50 OK
SECOND FLOOR PLAN - OTS - Width Mt. - 2.50 OK
TERRACE FLOOR PLAN - OTS - Area Sq.Mt. - 7.50 OK
TERRACE FLOOR PLAN - OTS - Width Mt. - 2.50 OK
[-] OTS Count Details
A (A) Number Of OTS(s) No. - 1 OK
[-] Arch. Projection and Balcony
A (A) GROUND FLOOR PLAN - Total Area Mt. - - OK
FIRST FLOOR PLAN - Total Area Mt. - - OK
SECOND FLOOR PLAN - Total Area Mt. - - OK
TERRACE FLOOR PLAN - Total Area Mt. - - OK
[-] Stair Count Details
A (A) GROUND FLOOR PLAN - Number Of Common Stair(s) No. 1 1 OK
GROUND FLOOR PLAN - Number Of Fire Stair(s) No. - - OK
FIRST FLOOR PLAN - Number Of Common Stair(s) No. 1 1 OK
FIRST FLOOR PLAN - Number Of Fire Stair(s) No. - - OK
SECOND FLOOR PLAN - Number Of Common Stair(s) No. 1 1 OK
SECOND FLOOR PLAN - Number Of Fire Stair(s) No. - - OK
TERRACE FLOOR PLAN - Number Of Common Stair(s) No. - 1 OK
TERRACE FLOOR PLAN - Number Of Fire Stair(s) No. - - OK
[-] Stair Details
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 1.00 1.00 OK
STAIRCASE - Tread Width Mt. 0.25 - 0.250 OK
STAIRCASE - Winder Width Mt. - - OK
STAIRCASE - Riser Height Mt. 0.19 0.176 OK
STAIRCASE - Riser No. On Flight No. 12 8 OK
STAIRCASE - Intermediate Landing Width Mt. 1.00 1.00 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
STAIRCASE - Railing Ht. Mt. 0.85 - 1.00 OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 1.00 1.00 OK
STAIRCASE - Tread Width Mt. 0.25 - 0.250 OK
STAIRCASE - Winder Width Mt. - - OK
STAIRCASE - Riser Height Mt. 0.19 0.176 OK
STAIRCASE - Riser No. On Flight No. 12 8 OK
STAIRCASE - Intermediate Landing Width Mt. 1.00 1.00 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
STAIRCASE - Railing Ht. Mt. 0.85 - 1.00 OK
SECOND FLOOR PLAN STAIRCASE - Flight Width Mt. 1.00 1.00 OK
STAIRCASE - Tread Width Mt. 0.25 - 0.250 OK
STAIRCASE - Winder Width Mt. - - OK
STAIRCASE - Riser Height Mt. 0.19 0.176 OK
STAIRCASE - Riser No. On Flight No. 12 8 OK
STAIRCASE - Intermediate Landing Width Mt. 1.00 1.00 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
STAIRCASE - Railing Ht. Mt. 0.85 - 1.00 OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.00 OK
STAIRCASE - Tread Width Mt. - - 0.250 OK
STAIRCASE - Winder Width Mt. - - OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. 12 - OK
STAIRCASE - Intermediate Landing Width Mt. - 1.00 OK
STAIRCASE - Cabin Ht. Mt. - - 2.70 OK
STAIRCASE - Railing Ht. Mt. - - 1.00 OK
[-] Compound Wall Check
Compound Wall ( HT=1.50mt.; GRILL HT=0.90mt. ) Side '-' Front OK
Area Mt. 11.51 OK
Total Height Mt. 1.50 1.50 OK
Compound Wall Height Mt. - 0.60 OK
Grill Height Mt. - 0.90 OK
Length Mt. - 7.67 OK
Side '-' Front OK
Area Mt. 7.91 OK
Total Height Mt. 1.50 1.50 OK
Compound Wall Height Mt. - 0.60 OK
Grill Height Mt. - 0.90 OK
Length Mt. - 5.27 OK
Side '-' Rear OK
Area Mt. 8.07 OK
Total Height Mt. 2.40 1.50 OK
Compound Wall Height Mt. 1.50 0.60 OK
Grill Height Mt. 0.90 0.90 OK
Length Mt. - 5.38 OK
[-] Room Details
  All Rooms are as per Rule in Room Checking


NOTE : Based on the aforesaid permission the applicant reserves the rights to commence the construction from the day of issuance. Nevertheless; in case, for procuring the aforesaid permission, any document or system configuration for rules or information or parameters or drawings provided or attached is found to be incorrect or inconsistent with respect to prevailing bye-laws, by any authority or otherwise, the permission granted shall be considered as lapsed.
Accuracy of Scrutiny Report and Drawing is subject to accuracy of end-user provided data, 3rd party software/hardware/services, etc. SoftTech Engineers Ltd. is not liable for any damages which may arise from use, or inability to use the Application.

[-] Rules
Topic Rule
Plot Level
Plot Area For any Residential use if plot is a part of approved layout plan then plot area may be less than 40 sqmt.{Building Construction and Development By-Laws 2018, Rule No. 3.2.1 }
Plot Width For any Residential use if plot is a part of approved layout plan then plot area may be less than 40 sqmt.{Building Construction and Development By-Laws 2018, Rule No. 3.2.1 }
Plot Depth For any Residential use if plot is a part of approved layout plan then plot area may be less than 40 sqmt.{Building Construction and Development By-Laws 2018, Rule No. 3.2.1 }
Access Width For Single dwelling Unit, The width of the main abutting road shall not be less than 9.00 mt.
Plot Frontage For any Residential use if plot is a part of approved layout plan then plot area may be less than 40 sqmt.{Building Construction and Development By-Laws 2018, Rule No. 3.2.1 }
Coverage Area For Residential use and Hostel, in location Existing Built Up Area/Developed Area ,if plot area is between 100-300 sq mt. then Max.Coverage shall be 65% applicable{Building Construction and Development By-Laws 2018, Rule No.3.5.1.(1)}
Additional Coverage Area -
FAR Area (1) For Residential use and Hostel, in location Existing Built Up Area/Developed Area ,if plot area is between 100-300 sq mt. then Max.FAR shall be 1.75 applicable{Building Construction and Development By-Laws 2018, Rule No.3.5.1.(1)}
(2) -
(3) For Residential use and Hostel, in location Existing Built Up Area/Developed Area ,if plot area is between 100-300 sq mt. then Max.FAR shall be 1.75 applicable{Building Construction and Development By-Laws 2018, Rule No.3.5.1.(1)}
(4) No Additional FAR is applicable
Consumed FAR (1) For Residential use and Hostel, in location Existing Built Up Area/Developed Area ,if plot area is between 100-300 sq mt. then Max.FAR shall be 1.75 applicable{Building Construction and Development By-Laws 2018, Rule No.3.5.1.(1)}
(2) -
(3) For Residential use and Hostel, in location Existing Built Up Area/Developed Area ,if plot area is between 100-300 sq mt. then Max.FAR shall be 1.75 applicable{Building Construction and Development By-Laws 2018, Rule No.3.5.1.(1)}
(4) No Additional FAR is applicable
Tree Number For the residential Use, for plot area less than 200 sq.mt.,one tree shall be required. {As per Building Construction and Development By-Laws 2018, rule no. 3.1.2.2}
Equivalent Car Space Parking Check FOR RESIDENTIAL BUILDING, FOR PLOT AREA 100-200 SQ. MT. ONE CAR SHALL BE REQUIRED {AS PER BUILDING CONSTRUCTION AND DEVELOPMENT BY-LAWS 2018, RULE NO.3.10}
Total Car Parking Check FOR RESIDENTIAL BUILDING, FOR PLOT AREA 100-200 SQ. MT. ONE CAR SHALL BE REQUIRED {AS PER BUILDING CONSTRUCTION AND DEVELOPMENT BY-LAWS 2018, RULE NO.3.10}
Margin Rule For Row House,plot area above 150 and up to 300 sq. mt., min front 3.0, rear 3.0 shall be required and side margins are not required {Building Construction and Development By-Laws 2018,Rule No. 3.4.1 (I) , (VI)}
'' ''
Tenement Density FOR RESIDENTIAL LAYOUT PLAN,MAX. 4 DWELLING UNIT FOR PLOT AREA 150-300SQMT.{BUILDING CONSTRUCTION AND DEVELOPMENT BY-LAWS 2018,RULE NO.26}
Compound Wall Check (1) Max 1.50m Height for Road abutting compound wall of corner plot shall be permissible as per the By laws table 7.47, Ref 3.8.2 Page 54
(2) Max 2.40m Height in which 0.9 is for Grill (from center line of the road) for Compound wall shall be permissible as per the By laws Ref 3.8.2 Page 54
Building Level
Building Height For Residencial Use, Maximum Height of construction shall be 10.50 mts (For Building without stilt/parking floor) from the level of the Building Unit.{Building Construction and Development By-Laws 2018, 3.4.1 }
Floor Height (1) For Terrace floor, atleast 1.0 mt. high and max. upto 1.5 mt. ht. Parapet wall shall be provided {Building Construction and Development By-Laws 2018,}
(2) For Terrace floor, atleast 1.0 mt. high and max. upto 1.5 mt. ht. Parapet wall shall be provided {Building Construction and Development By-Laws 2018,}
(3) For any Habitable Floor, minimum Floor height shall be 2.75 mts.{Building Construction and Development By-Laws 2018,}
(4) The plinth of the habitable area of any building shall be at a minimum height of 0.30mts from the established level of the building unit {Building Construction and Development By-Laws 2018, Rule No. 3.6.5, Page 51}
Floor Number For any Residential Single Dwelling unit without stilt Maximum Height of construction shall be 10.50 mts having max G+2 floor from the level of the Building Unit.{Building Construction and Development By-Laws 2018, 2.5.1.7 }
Carpet Area Check SPLIT A
OTS (1) Double height area and width should not be checked.
(2) -
OTS Count (1) Double height area and width should not be checked.
(2) -
StairCase Count (1) For any building having more than one Ground floor, Mini. one staircase has to be provided
(2) No staircase check should be mandatory for Terrace floor.
StairCase (1) For Residential Building,stairwidth shall be mini. 1.0 mt. with max riser upto 0.19 mt. and min. tread upto 0.25 mt.{Building Construction and Development By-Laws 2018, Rule No.3.8.1, Page 54}
(2) -
(3) For nay Residential Building, The number of risers shall be 12.00 per flight for Stairs.{Building Construction and Development By-Laws 2018,}
(4) For any use staircase check should not be mandatory on terrace floor.{Building Construction and Development By-Laws 2018, Rule No.3.8.1 }
(5) -
(6) For nay Residential Building, The number of risers shall be 12.00 per flight for Stairs.{Building Construction and Development By-Laws 2018,}
Building Level (Rooms)
Bed Room Minimum size of Any habitable room shall be 9.50 sq. mt.{Building Construction and Development By-Laws 2018, Rule No.3.6.1} ; -
Dining/kitchen Minimum size of habitable room shall be 9.50 sq. mt.{Building Construction and Development By-Laws 2018} ; -
Drawing Room Minimum size of Any habitable room shall be 9.50 sq. mt.{Building Construction and Development By-Laws 2018, Rule No.3.6.1} ; -
Living Minimum size of Any habitable room shall be 9.50 sq. mt.{Building Construction and Development By-Laws 2018, Rule No.3.6.1} ; -
Store No rule defined{Building Construction and Development By-Laws 2018, Rule No.3.6.1} ; -
Toilet Minimum size of Bath +WC room shall be 2.80 sq. mt.{Building Construction and Development By-Laws 2018} ; -